An Investigation of Magnetite Consumption at the Blackwater Coal Preparation Plant of Utah Development Company

Poor performance in the several stages of the magnetite recovery circuit, coupled with poor desliming through inefficient and over- loaded desliming screens, led to excessive magnetite consumption. An accurate and reliable sampling programme was established covering all outlets of the plant. Emphasis was placed on frequency of increments in an endeavour to detect extreme conditions of short duration. Systematic checking of the entry points to these outlets than identified those sections of the recovery circuit at fault, namely magnetite recovery separators and the heavy media cyclone product rinsing screens. More product rinsing water was provided, and modifications to the rinsing screens improved the efficiency of these units._x000D_
Consistency of operation through automatic control of level eliminated the sudden massive losses in the magnetic separators. Load on the recovery circuit was then reduced by improvements to the raw coal desliming screens. A 50 per cent reduction in magnetite consumption was achieved.
Return to parent product
  • An Investigation of Magnetite Consumption at the Blackwater Coal Preparation Plant of Utah Development Company
    PDF
    This product is exclusive to Digital library subscription
  • An Investigation of Magnetite Consumption at the Blackwater Coal Preparation Plant of Utah Development Company
    PDF
    Normal price $22.00
    Member price from $0.00
    Add to cart

    Fees above are GST inclusive

PD Hours
Approved activity
  • Published: 1974
  • PDF Size: 0.15 Mb.
  • Unique ID: P197404001

Our site uses cookies

We use these to improve your browser experience. By continuing to use the website you agree to the use of cookies.