In many operations the use of less electrochemically reactive grinding media in the first grinding stage (for example, rod milling and high aspect ratio SAG milling) is rarely considered. Therefore, in reality a plant may inadvertently be using a 'mixed' media charge. That is, whilst employing inert grinding media during secondary grinding, electrochemically active forged steel grinding media may be used in the primary grinding stage._x000D_
This paper discusses the impact of such a circuit on the pulp chemistry and flotation response of a refractory gold ore. The Wiluna concentrator has two grinding circuits operating in parallel. Line 1 operates a single ball mill in closed circuit with cyclones, and utilises high chrome grinding media, while the second circuit (Line 2) consists of a rod mill (with forged steel rods) in series with a ball mill, which also utilises high chrome grinding media. The cyclone overflows from both circuits are combined to feed a sulfide flotation circuit._x000D_
Pulp chemistry surveys were completed around both grinding circuits, and laboratory flotation tests were conducted on the cyclone overflows. The results demonstrate clearly that the rod mill/ball mill circuit operated at significantly lower Eh and dissolved oxygen values, while the percentage EDTA extractable iron was considerably higher, when compared to the single stage ball milling circuit. These variations in pulp chemistry had a marked negative impact on the laboratory rougher flotation response, and suggests that plant performance may be affected._x000D_
FORMAL CITATION:Greet, C J and Bartle, C, 2008. Mixed media grinding - a refractory gold case study, in Proceedings MetPlant 2008, pp 273-286 (The Australasian Institute of Mining and Metallurgy: Melbourne).
This paper discusses the impact of such a circuit on the pulp chemistry and flotation response of a refractory gold ore. The Wiluna concentrator has two grinding circuits operating in parallel. Line 1 operates a single ball mill in closed circuit with cyclones, and utilises high chrome grinding media, while the second circuit (Line 2) consists of a rod mill (with forged steel rods) in series with a ball mill, which also utilises high chrome grinding media. The cyclone overflows from both circuits are combined to feed a sulfide flotation circuit._x000D_
Pulp chemistry surveys were completed around both grinding circuits, and laboratory flotation tests were conducted on the cyclone overflows. The results demonstrate clearly that the rod mill/ball mill circuit operated at significantly lower Eh and dissolved oxygen values, while the percentage EDTA extractable iron was considerably higher, when compared to the single stage ball milling circuit. These variations in pulp chemistry had a marked negative impact on the laboratory rougher flotation response, and suggests that plant performance may be affected._x000D_
FORMAL CITATION:Greet, C J and Bartle, C, 2008. Mixed media grinding - a refractory gold case study, in Proceedings MetPlant 2008, pp 273-286 (The Australasian Institute of Mining and Metallurgy: Melbourne).
Contributor(s):
C J Greet, C Bartle
-
Mixed Media Grinding - A Refractory Gold Case StudyPDFThis product is exclusive to Digital library subscription
-
Mixed Media Grinding - A Refractory Gold Case StudyPDFNormal price $22.00Member price from $0.00
Fees above are GST inclusive
PD Hours
Approved activity
- Published: 2008
- PDF Size: 0.16 Mb.
- Unique ID: P200807020