Skip to main content
Conference Proceedings

Mine Planning and Equipment Selection (MPES) 2010

Conference Proceedings

Mine Planning and Equipment Selection (MPES) 2010

PDF Add to cart

Infrared Imager as a Tool for Monitoring of Power Shovels, Gearcase Bearings and Electric Motors

Thermal method of diagnostic as a nondestructive monitoring is based on data logging of infrared radiation from heated surface or from the associated thermal field. Monitoring of gearcases and motors hidden faults, such as, bearing degradation (deep-seated wears and tears, fretting wear, spalling and jamming solids of revolution) is closely related to high variations in temperature. The use of portable thermal imaging devices provides considerable advantages due to: easy remote access to the unit under test even when it is operating; minimum time required to obtain information and an opportunity for a real-time diagnosis of the tested subject's condition._x000D_
FORMAL CITATION:Sergeev, V, Zhuravlev, M and Poderni, R Y, 2010. Infrared imager as a tool for monitoring of power shovels, gearcase bearings and electric motors, in Proceedings Mine Planning and Equipment Selection (MPES) 2010, pp 365-368 (The Australasian Institute of Mining and Metallurgy: Melbourne).
Return to parent product
  • Infrared Imager as a Tool for Monitoring of Power Shovels, Gearcase Bearings and Electric Motors
    PDF
    This product is exclusive to Digital library subscription
  • Infrared Imager as a Tool for Monitoring of Power Shovels, Gearcase Bearings and Electric Motors
    PDF
    Normal price $22.00
    Member price from $0.00
    Add to cart

    Fees above are GST inclusive

PD Hours
Approved activity
  • Published: 2010
  • PDF Size: 0.748 Mb.
  • Unique ID: P201011037

Our site uses cookies

We use these to improve your browser experience. By continuing to use the website you agree to the use of cookies.