Optimisation of Copper Electrowinning at BHAS
Since the commissioning of the BHAS Copper Plant in 1984 the copper electrowinning operations have not fully met expectations. During 1988, a laboratory scale electrowinning unit was constructed to enable an investigation of the effects of process parameters on copper cathode deposition and quality._x000D_
The process parameters investigated were copper concentration, acid concentration, current density, electrolyte temperature, electrolyte flow, electrolyte impurities and electrolyte additives._x000D_
The findings of this research program indicate that there is an optimum cathode deposition morphology which results in good quality copper deposits which have improved stripping characteristics. All of the process variables investigated influenced the copper deposition and therefore it was necessary to delineate a suitable operating envelope for the copper electrowinning. As a result new standard operating parameters in electrowinning have been implemented which has enabled the production of higher quality copper cathodes with improved stripping characteristics.
The process parameters investigated were copper concentration, acid concentration, current density, electrolyte temperature, electrolyte flow, electrolyte impurities and electrolyte additives._x000D_
The findings of this research program indicate that there is an optimum cathode deposition morphology which results in good quality copper deposits which have improved stripping characteristics. All of the process variables investigated influenced the copper deposition and therefore it was necessary to delineate a suitable operating envelope for the copper electrowinning. As a result new standard operating parameters in electrowinning have been implemented which has enabled the production of higher quality copper cathodes with improved stripping characteristics.
Contributor(s):
D J Readett, C J Mark
-
Optimisation of Copper Electrowinning at BHASPDFThis product is exclusive to Digital library subscription
-