Condition Monitoring and Maintenance of Underground Load-Haul-Dump Machines
At the LKAB, Iron Ore Mine, Kiruna, Sweden a preliminary investigation into the reliability characteristics of a fleet of load- haul-dump machines has shown that the hydraulic system is one of the most critical parts. Therefore, hydraulic system was selected for study and analysis through condition monitoring devices so that failure can be controlled or at least the failure consequences can be minimized._x000D_
The hydraulic system has two different problems; one is that the contamination level is too high and the other is high temperature during operation. At high temperature, seals and tubes are a problem, because they stiffen due to carbonization, which leads to increasing leakage. The pumps and restrictions were responsible for the main temperature increase.
The hydraulic system has two different problems; one is that the contamination level is too high and the other is high temperature during operation. At high temperature, seals and tubes are a problem, because they stiffen due to carbonization, which leads to increasing leakage. The pumps and restrictions were responsible for the main temperature increase.
Contributor(s):
E Biledt
-
Condition Monitoring and Maintenance of Underground Load-Haul-Dump MachinesPDFThis product is exclusive to Digital library subscription
-
Condition Monitoring and Maintenance of Underground Load-Haul-Dump MachinesPDFNormal price $22.00Member price from $0.00
Fees above are GST inclusive
PD Hours
Approved activity
- Published: 1991
- PDF Size: 0.409 Mb.
- Unique ID: P199106010