Conference Proceedings
Smelting and Refining Operators' Symposium, North Queensland
Conference Proceedings
Smelting and Refining Operators' Symposium, North Queensland
Development of a Coal Mass Flow Monitor
The coal mass flow monitor was developed to measure the instantaneous mass flow rate of pulverised coal to the copper reverberatory furnace at Mount Isa. The instrument was calibrated with an isokinetic coal sampler which was installed immediately downstream from the coal mass flow monitor._x000D_
Readings from the coal mass flow monitor were used to control the feedrate of coal to the furnace and this helped to stabilise the furnace operation._x000D_
Coal samples obtained from the isokinetic coal sampler were also sized using a Leeds and Northrup Microtrac analyser. The coal size was critical to reverberatory furnace performance. These developments significantly improved the overall combustion control of the furnace and gains of ten percent were made in the furnace thermal efficiency. Testwork on an auxiliary arch coal burner is also reported.
Readings from the coal mass flow monitor were used to control the feedrate of coal to the furnace and this helped to stabilise the furnace operation._x000D_
Coal samples obtained from the isokinetic coal sampler were also sized using a Leeds and Northrup Microtrac analyser. The coal size was critical to reverberatory furnace performance. These developments significantly improved the overall combustion control of the furnace and gains of ten percent were made in the furnace thermal efficiency. Testwork on an auxiliary arch coal burner is also reported.
Contributor(s):
J B Cunningham, M J Fox, R G Henley, N R Whitworth
-
Development of a Coal Mass Flow MonitorPDFThis product is exclusive to Digital library subscription
-
Development of a Coal Mass Flow MonitorPDFNormal price $22.00Member price from $0.00
Fees above are GST inclusive
PD Hours
Approved activity
- Published: 1985
- PDF Size: 0.461 Mb.
- Unique ID: P198501010