Skip to main content
Conference Proceedings

10th Mill Operators' Conference 2009

Conference Proceedings

10th Mill Operators' Conference 2009

PDF Add to cart

Advances in Dense Medium Cyclone Plant Design

In coal preparation, large dense medium cyclones (DMC) at low pressure heads (typically 9D where D = cyclone diameter) are the norm. This contrasts with high density mineral applications where, largely for historical reasons, smaller cyclones at high heads are the standard. There are advantages in preferring large diameter cyclones at low heads, assuming that metallurgical performance does not suffer significantly. These include simpler plant layouts, easier maintenance, smaller spares inventories, reduced wear, reduced medium pumping demands, smaller buildings and overall lower capital and operating costs. In 2008, therefore, Xstrata Zinc decided to trial a single DSM-design 800 mm cyclone in one of its four DMC lines at Mt Isa, replacing the four 400 mm cyclones previously installed. Circumstances allowed a low head of 9.5 D to be trialled, compared with the existing 400 mm head of 21.5 D._x000D_
This paper describes the trial, including tests using painted ore particles as tracers, estimates of yield and metal recovery, and wear monitoring. The larger unit performed well. There was no evidence that metallurgical performance in terms of metal recovery and waste reject rate suffered, and there was some evidence that it may have improved. Cyclone life increased, and preliminary data suggest that the replacement cost of the 800 mm cyclones is less than half that of the 400 mm units, and this is expected to improve. The plant layout and operability have also improved significantly. Xstrata has therefore decided to convert the whole plant to four low head 800 mm units, replacing the original 16 high head 400 mm units._x000D_
The paper includes an explanation of the effect of static head on DMC separating force. It also reviews earlier research on diamond applications, and applies a general DMC process model to the Xstrata case, both of which confirm that large, low head cyclones are appropriate in mineral applications, contrary to conventional practice. Such units could significantly reduce both the capital and operating costs of DMC plants in mineral applications.
Return to parent product
  • Advances in Dense Medium Cyclone Plant Design
    PDF
    This product is exclusive to Digital library subscription
  • Advances in Dense Medium Cyclone Plant Design
    PDF
    Normal price $22.00
    Member price from $0.00
    Add to cart

    Fees above are GST inclusive

PD Hours
Approved activity
  • Published: 2008
  • PDF Size: 2.415 Mb.
  • Unique ID: P200911006

Our site uses cookies

We use these to improve your browser experience. By continuing to use the website you agree to the use of cookies.