Conference Proceedings
XXV International Mineral Processing Congress (IMPC) 2010
Conference Proceedings
XXV International Mineral Processing Congress (IMPC) 2010
Application of the Anaconda Simplified Work Index for Multiple Test Sizes
Application of the Anaconda Simplified Work Index for Multiple Test Sizes Vale uses Bond Work Index measurements extensively in a number of applications. The Bond Work Index is usually a good parameter for checking scale up procedures when sizing ball mills, as well as the basis for variability analysis whenever drill core data is available. It is typical to measure between 100 and 150 Bond Work Indexes, depending on the deposit characteristics. The Bond procedure is relatively complex and time costly. It also requires relatively large amounts of sample, which are very expensive to be obtained. The benefits of the Anaconda simplified procedure are: considerably smaller sample requirements and laboratory time. This makes it very much attractive at Vale's development centre, including geometallurgical mapping, operation efficiency control, mine to mill, etc._x000D_
The Anaconda simplified procedure was implemented and evaluated at Vale's Development Centre using a number of ores and several samples of each ore totalling more than 190 measurements. The Anaconda simplified method was calibrated for several test sieves and a correlation for any test size was determined for Vale's test mill. The calibration was also extended for two sample top sizes. The relative error of the simplified procedure was found to be in the range of nine per cent which is within the expected error Bond standard procedure._x000D_
The implementation of the Anaconda method at Vale's development center has been used with great success over the past years in several green field, brown field projects and operating plants.
The Anaconda simplified procedure was implemented and evaluated at Vale's Development Centre using a number of ores and several samples of each ore totalling more than 190 measurements. The Anaconda simplified method was calibrated for several test sieves and a correlation for any test size was determined for Vale's test mill. The calibration was also extended for two sample top sizes. The relative error of the simplified procedure was found to be in the range of nine per cent which is within the expected error Bond standard procedure._x000D_
The implementation of the Anaconda method at Vale's development center has been used with great success over the past years in several green field, brown field projects and operating plants.
Contributor(s):
V K Alves, C L Schneider
-
Application of the Anaconda Simplified Work Index for Multiple Test SizesPDFThis product is exclusive to Digital library subscription
-
Application of the Anaconda Simplified Work Index for Multiple Test SizesPDFNormal price $22.00Member price from $0.00
Fees above are GST inclusive
PD Hours
Approved activity
- Published: 2010
- PDF Size: 0.49 Mb.
- Unique ID: P201007062