Development of the Primary Ventilation System at Mount Isa: III. Engineering Design and Erection

A contract for three 20 ft diameter vertically mounted axial flow fans of the same aerodynamic design, was placed by Mount ]sa Mines Limited in 1963. The hydraulic blade pitch changing mechanism, the method of blade fabrication, and the roll out centre casings are features of these fans. Protection devices and fan control are designed for unattended operation and remote control. The erection and commissioning of the fans during 1964-65 is described.